IEC 60312-1 sets out how to measure the performance of dry household vacuum cleaners: how much dust they pick up from carpets and hard floors, how much fine dust they let back into the room, and a range of other characteristics. Its European version, EN 60312-1:2017, is the standard used to check dry vacuum cleaners against EU and UK ecodesign requirements. Airmid Healthgroup tests to the dust pick-up and dust re-emission parts of the standard.

Internationally, the IEC withdrew IEC 60312-1 in 2016 and replaced it with IEC 62885-2, now in its 2021 edition. If you are working to the current international standard, see our IEC 62885-2 testing page.

Full title
Vacuum cleaners for household use – Part 1: Dry vacuum cleaners – Methods for measuring the performance
Versions
IEC 60312-1:2010 with Amendment 1:2011 (withdrawn by the IEC in 2016) · EN 60312-1:2017 and amendment A11:2022 (European version)
Replaced by
IEC 62885-2:2016, revised as IEC 62885-2:2021
Covers
Mains-powered dry vacuum cleaners for household use. Battery-operated cleaners are outside its scope.
Committee
IEC TC 59/SC 59F, Surface cleaning appliances
Airmid tests
Dust removal from carpets, hard flat floors, hard floors with crevices and along walls · total emission while vacuum cleaning · filtration efficiency and dust re-emission
Sample and turnaround
Six units of the model · 4 weeks from receipt of samples

What IEC 60312-1 measures, and what we test

The standard defines the performance characteristics that matter to users and gives a test method for each. Clause 5 covers the cleaning tests below. Clause 6 covers practical and mechanical characteristics such as motion resistance, cleaning under furniture, radius of operation, impact and bump tests, hose tests, life test, mass, dimensions, noise level and energy consumption.

Clause Dry vacuum cleaning test Airmid
5.1 Dust removal from hard flat floors ✓ Tested
5.2 Dust removal from hard floors with crevices ✓ Tested
5.3 Dust removal from carpets ✓ Tested
5.4 Dust removal along walls ✓ Tested
5.5 Fibre removal from carpets and upholstery
5.6 Thread removal from carpets
5.7 Maximum usable volume of the dust receptacle
5.8 Air data
5.9 Performance with loaded dust receptacle
5.10 Total emission while vacuum cleaning ✓ Tested
5.11 Filtration efficiency of the vacuum cleaner ✓ Tested

Clause numbers follow IEC 60312-1:2010 with Amendment 1:2011. EN 60312-1:2017 and IEC 62885-2 number some tests differently.

The standard itself notes that most of its methods “will give more reliable results when applied for comparative testing of a number of appliances at the same time, in the same laboratory and by the same operator”. That makes it well suited to benchmarking a new model against earlier versions or competitor products in one programme.

How dust pick-up testing works

  1. Condition. The cleaner is run in and conditioned before testing, and tests take place under controlled atmospheric conditions.
  2. Prepare the test area. Standard test dust is spread on a hard flat floor, packed into a crevice set into a hard floor, laid along a wall edge, or worked into a test carpet.
  3. Clean. The cleaning head makes a set number of double strokes, each one forward and one backward movement at a uniform speed over a specified stroke length.
  4. Weigh. The dust removed is weighed and expressed as a ratio of the dust applied: the dust pick-up.
  5. Correct. Carpet results are corrected against a reference cleaner system run on the same test carpet, so that results stay comparable as the carpet ages.

How dust re-emission and filtration testing works

A known amount of test dust is fed into the suction inlet of the vacuum cleaner. Particles from 0.3 to 10 micrometres in the exhaust air are counted and compared with those entering, giving dust re-emission as a percentage.Test dust fed to suction inletKnown amount of 0.3–10 µm particles inVacuum cleaner under testBag or binFiltersExhaust airParticle counting0.3–10 µm particles emittedDust re-emission (%)particles out ÷ particles in × 100
Simplified schematic of the dust re-emission principle. Not to scale.

Picking up dust is only half the job. Fine particles that pass through the bag, filters, seals or housing go straight back into the room air, and fine particles are the ones most likely to carry allergens.

Filtration efficiency and dust re-emission. A specific amount of test dust is fed into the suction inlet. Particles from 0.3 to 10 µm in the air leaving the cleaner are counted and compared with the particles of the same size range going in. EU ecodesign rules use this figure, dust re-emission, expressed as a percentage to two decimal places.

Total emission while vacuum cleaning. This test looks at emissions from the whole appliance while it is cleaning, rather than the filter alone, so seals, bags and the housing are captured as well as the exhaust.

EU and UK ecodesign limits measured with EN 60312-1

Regulation (EU) No 666/2013 sets ecodesign requirements for mains-powered dry vacuum cleaners. EN 60312-1:2017 provides the measurement methods, and the UK lists it as a designated standard for the same requirements. The limits that took effect on 1 September 2017 are:

≥ 0.75dust pick-up on carpet (not required for hard floor vacuum cleaners)
≥ 0.98dust pick-up on hard floor (not required for carpet vacuum cleaners)
≤ 1.00%dust re-emission of 0.3–10 µm particles
Requirement from 1 September 2017 Limit Airmid
Dust pick-up on carpet (dpuc) ≥ 0.75 ✓ Tested
Dust pick-up on hard floor (dpuhf) ≥ 0.98 ✓ Tested
Dust re-emission ≤ 1.00% ✓ Tested
Annual energy consumption < 43.0 kWh/year
Rated input power < 900 W
Sound power level ≤ 80 dB(A)
Hose durability Usable after 40,000 oscillations under strain
Operational motor lifetime ≥ 500 hours

The regulation does not apply to wet, wet-and-dry, battery-operated, robot, industrial or central vacuum cleaners. The separate EU energy label for vacuum cleaners was annulled by the EU General Court in November 2018. That ruling did not affect the ecodesign requirements. The EU has been reviewing its vacuum cleaner rules since 2019, so check for updates before relying on these figures for a new product.

Standard test dust and real-world performance

EN 60312-1 uses artificial test dust so that results are repeatable and comparable between laboratories. That is its strength, but test dust is not house dust. Our own work comparing ISO fine test dust with real household dust found the test dust was much finer than household dust and very different in make-up. Read the interview with Dr Angela Southey.

If you want to make allergen, hygiene or air quality claims, pair the standard tests with methods that use real allergens and particles:

Airmid is a designated laboratory for the Asthma & Allergy Friendly® Certification Program. Read how vacuum cleaner certification works.

IEC 60312-1, EN 60312-1 or IEC 62885-2: which do you need?

Standard Status Use it when
IEC 60312-1:2010 (+A1:2011) Withdrawn by the IEC in 2016 A customer specification or earlier data set still refers to it
EN 60312-1:2017 (+A11:2022) European standard You need to show a dry vacuum cleaner meets EU or UK ecodesign requirements
IEC 62885-2:2021 Current international standard You are running an international test programme or writing a new specification

Other parts of the IEC 62885 series cover other appliance types, including IEC 62885-4 for cordless dry vacuum cleaners and IEC/ASTM 62885-7 for dry-cleaning robots.

Ordering a test

  • Sample: six units of the model to be tested.
  • Turnaround: 4 weeks from receipt of samples.
  • Tell us: whether the cleaner is a carpet, hard floor or general purpose model, which nozzles it ships with, which edition of the standard you need results against, and whether you want competitor or previous models tested alongside it.

Frequently asked questions

What is IEC 60312-1?

IEC 60312-1 is the international standard that sets out methods for measuring the performance of dry vacuum cleaners for household use, including dust pick-up from carpets and hard floors, dust re-emission, air data, noise and energy consumption. It is titled Vacuum cleaners for household use – Part 1: Dry vacuum cleaners – Methods for measuring the performance.

Is IEC 60312-1 still valid?

The IEC withdrew IEC 60312-1 in 2016 and replaced it with IEC 62885-2, which was revised in 2021. The European version, EN 60312-1:2017, is still used to measure dry vacuum cleaners against EU and UK ecodesign requirements.

What is the difference between IEC 60312-1 and EN 60312-1?

IEC 60312-1 is the international standard published by the IEC. EN 60312-1:2017 is the European version published by CENELEC and amended by A11:2022. EN 60312-1:2017 provides the measurement methods for EU vacuum cleaner ecodesign requirements and is a designated standard in the UK.

What is dust re-emission?

Dust re-emission is the percentage of dust particles from 0.3 to 10 µm that a vacuum cleaner emits, compared with the particles of the same size range entering its suction inlet when it is fed a specific amount of dust. Under EU ecodesign rules, dust re-emission must be no more than 1.00%.

What dust pick-up do EU ecodesign rules require?

From 1 September 2017, Regulation (EU) No 666/2013 set minimum dust pick-up of 0.75 on carpet and 0.98 on hard floor. The carpet requirement does not apply to hard floor vacuum cleaners, and the hard floor requirement does not apply to carpet vacuum cleaners.

Does EN 60312-1 cover cordless or robot vacuum cleaners?

No. IEC 60312-1 is not intended for battery-operated vacuum cleaners, and the EU ecodesign regulation excludes battery-operated and robot vacuum cleaners. Cordless dry vacuum cleaners are covered by IEC 62885-4 and dry-cleaning robots by IEC/ASTM 62885-7.

What is IEC 60312-2?

IEC 60312-2 covered the performance of wet cleaning appliances for household use. The IEC withdrew it in 2014 and replaced it with IEC 62885-3.

Which IEC 60312-1 tests does Airmid carry out?

Airmid tests dust removal from carpets, hard flat floors, hard floors with crevices and along walls, total emission while vacuum cleaning, and filtration efficiency and dust re-emission. We need six units of the model, and turnaround is 4 weeks from receipt of samples.

Sources

  1. IEC 60312-1:2010, Vacuum cleaners for household use – Part 1: Dry vacuum cleaners – Methods for measuring the performance. IEC Webstore
  2. IEC 60312-2:2010, Vacuum cleaners for household use – Part 2: Wet cleaning appliances – Methods of measuring the performance. IEC Webstore
  3. Commission Regulation (EU) No 666/2013 on ecodesign requirements for vacuum cleaners. EUR-Lex
  4. European Commission, Guidelines accompanying the ecodesign requirements for vacuum cleaners (2019). PDF
  5. UK Government, designated standards notice for vacuum cleaners (2021). PDF

Need dust pick-up or dust re-emission data?

Talk to our team about EN 60312-1 testing, or a combined programme with allergen and airborne particle tests for your product claims.

Request a quote

Related Resources

Client case studies

View all case studies

Submit Your Enquiry

This field is for validation purposes and should be left unchanged.
Contact Name(Required)

Not sure which test your product needs?

Filter all of our testing services and test methods by industry, product category, standard and topic in the Test Navigator.

Open the Test Navigator →
Scroll to Top