Air Cleaner Technology Testing and Nanoparticle Removal Efficiency: Airmid Healthgroup at ASHRAE 2026

ASHRAE 2026 Annual Conference logo, Austin, Texas, where Airmid Healthgroup presents research on nanoparticle removal efficiency and bioaerosol reduction
Airmid Healthgroup and the iAIR Group are active at the 2026 ASHRAE Annual Conference in Austin Texas presenting independent research on nanoparticle removal efficiency bioaerosol reduction and air cleaning technology performance

Airmid Healthgroup’s air cleaner technology testing is taking centre stage at the 2026 ASHRAE Summer Conference in Austin this week, with Dr. John McKeon presenting new research conducted in Airmid’s specialist 28.5m³ environmental chamber. The study examines the nanoparticle removal efficiency of a novel air purification system, addressing growing public health concern around indoor exposure to nanoparticles from outdoor pollution sources including wildfires, industrial emissions and tire wear.

Air Cleaner Technology Testing: Nanoparticle Removal Efficiency Study AU-26-C077

Dr. John McKeon is presenting new research at ASHRAE 2026 conducted using Airmid Healthgroup’s specialist environmental chamber facilities. The study (AU-26-C077), presented on Sunday, June 28, evaluates the filtration performance of a novel air purification system incorporating proprietary technology with dedicated airflow specifically targeting airborne nanoparticles.

The research addresses a growing public health concern: the contribution of outdoor pollution sources, including wildfires, industrial emissions and tire wear, to indoor nanoparticle exposure. These sources generate carbonaceous nanoparticles, microplastics and PM2.5, as well as particulate matter and volatile organic compounds, all of which can infiltrate indoor environments with potential impacts on occupant health.

Airmid Healthgroup's 28.5m³ environmental aerobiology test chamber used for nanoparticle removal efficiency and airborne pathogen testing, Dublin
Airmid Healthgroups 285m³ environmental aerobiology test chamber used to evaluate nanoparticle removal efficiency airborne pathogen reduction and air cleaning technology performance under controlled indoor conditions

Testing was conducted in a controlled 28.5m³ environmental chamber, with nanoparticles of average dimensions 10-20nm width and 2-3µm length aerosolised into the chamber. Particle counts were monitored across a 60-minute test duration, and gravimetric sampling was used to assess particle mass reduction. Performance was compared against natural decay with the proprietary technology switched off.

The system achieved a 92.5% reduction in airborne nanoparticles within 60 minutes. Gravimetric analysis showed a 63.6% reduction in particle mass after 30 minutes. Further testing is planned to assess performance against carbonaceous nanoparticles and volatile organic compounds, and to monitor potential byproducts during device operation.

iAIR Institute Scientific Leadership Forum

Speakers at the iAIR Institute Scientific Leadership Forum: Dr. John McKeon, CEO of Allergy Standards Limited, and Dr. Jessica Green, ARPA-H Program Manager for Resilient Systems, discussing airborne pathogens at ASHRAE 2026
Dr John McKeon and Dr Jessica Green lead the conversation on airborne pathogens indoor air quality and healthy building design at the iAIR Institute Scientific Leadership Forum ASHRAE Annual Conference Austin TX June 2026

Airmid Healthgroup is proud to support the iAIR Institute Scientific Leadership Forum taking place on Monday, June 29, at Cedar Door, Austin, from 6:00 PM. The leadership conversation begins at 7:00 PM. Dr. John McKeon will be in conversation with Dr. Jessica Green, Program Manager for Resilient Systems at ARPA-H, exploring airborne health risks, indoor air quality and the science of healthier buildings. The event is supported by Knauf North America.

To request an invitation, please email emmagribben@allergystandards.com.

ASHRAE Standards and Committee Activity

Beyond the research presentation, Dr. McKeon is participating in a series of ASHRAE committee and technical working group meetings, including the Environmental Health Committee, the Center of Excellence for Indoor Environmental Quality, reactive air and surface technologies, UV-related technical discussions, and air-cleaner standards development. These forums directly inform the standards landscape within which Airmid’s testing programmes operate. Dr. McKeon also takes up the position of President-Elect of the ASHRAE Ireland Chapter on 1 July 2026.

If you are attending ASHRAE 2026 and would like to connect with the Airmid team, or if you would like a summary of the research findings following the conference, please contact us at info@airmidhealthgroup.com.

Related Services at Airmid Healthgroup

Room Air Cleaner & Portable Air Purifier Performance Testing

Purpose-Built Bioaerosol Chambers for Infectious Aerosols & Airborne Pathogen Testing

Customised Aerobiology Chamber Set Up for Bespoke Projects

Related Blogs

ASHRAE 62.1 Indoor Air Quality Procedure (IAQP) – What You Need to Know

ASHRAE President Bill McQuade Visits Airmid to Explore the Future of Healthy Buildings

Claims Verification Services at Airmid Healthgroup

Scroll to Top